Developers: | Delta Electronics |
Technology: | UPS - Uninterruptible power supply units |
Content |
Ultron H-Series is 3-phase uninterruptible power supply units with double conversion.
Appointment
UPSes are aimed at use with the equipment in the banking and industrial sector, server premises, small data acquisition and processing centers, medical institutions. Reservation of an entrance power supply due to bypass input guarantees high reliability of a power supply of crucial applications.
The built-in function of a manual bypass allows to make service without interruption of a power supply of loading. Depending on your requirements you can select models 3f/3f or 3f/1f.
Specific Features
- Possibility of reservation according to the scheme "hot STANDBY".
- Automatic switching to a bypass for uninterrupted power of loading in case of internal fault of the UPS. Models 3f/3f and 3f/1f.
- Different communication ports for remote control from the computer using special software.
- Built-in mechanical switch of a bypass.
- Function of local and remote abnormal switching off of the inverter (EPO).
- Add-on battery modules are available to increase in battery life.
- The high coefficient of input power reduces operating costs of an electric unit.
- Economy mode for reduction of operating costs and costs for power supply.
- Broad range of input voltages reduces the probability of use of the battery that prolongs the term of its service.
Specifications
Model | H-15K (3/1) / H-15K (3/3) H-20K (3/1) / H-20K (3/3) H-30K (3/3)
|
---|---|
Power | [H-15K (3/1), H-15K (3/3)]: 15 kVA / 12 kW [H-20K (3/1, H-20K (3/3)]: 20 kVA / 16 kW [H-30K (3/3)]: 30 kVA / 24 kW |
Input | |
Rated voltage | 380 / 220, 400/230, 415 / 240 V Lanes of current (3 phases, 4 conductors plus grounding) |
tension Range | 270 ~ 485 V Lanes of current (phase phase) / 156 ~ 280 V Lanes of current (phase neutral) |
Electrical power factor | > 0.95 |
Frequency | 50 Hz / 60 Hz ± 3 Hz |
Exit | |
Tension | 3/3 model: 220 V / 380 V, 230 V / 400 V, 240 V / 415 V Lanes of current (3 phases, 4 conductors plus grounding) 3/1 models: 220 V / 230 V / 240 V Lanes of current (1 phase) |
Total coefficient. tension harmonics | <3% (at linear loading) |
voltage regulation Limits | ± 2% |
Frequency | 50 Hz / 60 Hz ± 0.1 Hz |
tension Form | Sine signal |
Overload capacity | 102 ~ 125%: 1 minute 125 ~ 150%: 30 seconds > 150%: The 2nd second |
Accumulator and charger | |
Rated Voltage | 240 In a post. current |
charge Current | [H-15K (3/1), H-15K (3/3)]: 2.6A [H-20K (3/1, H-20K (3/3)]: 5.2A [H-30K (3/3)]: 5.2A |
Electric connection | Terminal jumpers |
Interfaces | |
Standard | RS 232 x 1, slot of SNMP x 1, AS400 x 1, Dry contact x 1 |
Compliance to standards | |
Security and EMS | CE, EN62040-1 |
Other | |
Emergency power off | Local and remote |
Remote control | It is built-in |
Add-on battery pack | Option (2 types: 26 A or 40 A) |
Normal mode | 3/3 model: 90% (at an overall load) 3/1 models: 90% (at an overall load) |
Economy mode | 3/3 model: 97% (at an overall load) 3/1 models: 97% (at an overall load) |
Environment | |
Working temperature | 0 ~ 40ºC |
Relative humidity | 5% ~ 95% (without formation of condensate) |
Noise level (at distance of 1 m) | <60 dB(A) |
Total characteristics | |
the UPS Overall dimensions (Highway x In x) | 380 x 650 x 860 mm |
UPS Weight | 108 kg |