SmartOnline SU40KX

Product
The name of the base system (platform): Tripp Lite SmartOnline
Developers: Tripp Lite
Technology: UPS - Uninterruptible power supply units

SmartOnline SU40KX is the modular 3-phase UPS of the SmartOnline series with a power of 40 kVA, UPS online with double conversion performed by it agrees to international standards

Description

File:SU60KX-FRONT-L.jpg
  • 40000 VA 3-phase UPS (40 kVA) of vertical type
  • The modular architecture of ensuring reliability of N+1 helps to achieve 100% of readiness of a system
  • Parallel inclusion according to scheme 1+1 for reliability augmentation of a system or increase in power is allowed
  • Low total values of non-linear distortions reduce cost of installation due to use of the generator with a ratio 1:1 to loading
  • 3-phase wire connection of an input and exit (220/380 V, 230/400 V or 240/415 V, 3 phases, 4 wires + earth, connection by a star)
  • Technology of the IGBT conversion and zero switching time, online mode with double conversion
  • Operating time lasts adding of modules of external batteries

File:SU60KX-BACK-L.jpg

Main Characteristics

  • N+1 configuration: if carrying out service is required, it is possible to replace any of two complete, reliable power modules of 20 kVA without power off of loading
  • Configuration 1+1: Two SU40KX UPSes can be connected in parallel to ensure or trouble-free and reliable operation of the equipment, or to increase power on a power supply
  • The big electrical power factor, the improved technology of the IGBT conversion and technology of digital signal processing (DSP) provide low total nonlinear distortion coefficient (THDi).
  • Low total values of non-linear distortions (less than 3%) reduce cost of installation due to use of the generator with a ratio 1:1 to loading
  • Exclusively effective work (up to 97%) allows to save means due to decrease in electricity consumption.
  • Interactive work, double conversion using IGBT technology provide the alternating voltage of the correct sinusoidal form at the exit
  • Continuous work with instant switching at power supply failures, fluctuations of tension and impulse interference in network is supported
  • Non-linear distortions, electrical impulse interference, fluctuations of frequency and other difficult solved problems with power supply are eliminated
  • Power output is 40000 BA/32000 VT, 3-phase wire connections of an input and exit
  • Adjustment of tension with the broad range: 173 – 300 V/276-477 V ~.
  • Internal power modules and blocks of batteries are located in one vertical compartment occupying the small space indoors. Normal operating time at a half/overall load is 13 min./5.5 min. * Operating time from batteries can be prolonged due to connection of add-on external units of batteries (the BP480V26B and BP480V40C models; are purchased separately, service life batery up to 7 years.).
  • The front panel is equipped with a set of LEDs and the LCD display to which the screen with the event log can be brought, registered in real time. Capacity of the magazine is up to 500 events.
  • The screen of dynamic control of the battery optimizes operation of the battery for prolongation of its service life and allows to execute cold start of the UPS
  • The built-in port of communication RS-232 works with PowerAlert software for issue of a command of switching off and record of the report for one server
  • The connector of connection of accessories can be used for installation of the card (SNMPWEBCARD model) with management through SNMP for remote switching off, reset and other functions
  • The button of abnormal switching off (EPO function) switches off the UPS and disconnects a bypass chain
  • The built-in interface with dry contacts for the EPO function supports remote emergency shutdown in the conditions of large objects.