Developers: | CyberPower |
Date of the premiere of the system: | 2019/03/25 |
Last Release Date: | 2019/09/10 |
Technology: | UPS - Uninterruptible power supply units |
Content |
CyberPower an OL series includes the UPS of double conversion with a net signal sine signal. Devices of a series are intended for protection of crucial devices, such as storage systems and servers, video recorders and observation systems, network and peripheral equipment, systems of abnormal power supply.
2019
OL5KERTHD и OL6KERTHD
On September 10, 2019 the CyberPower company provided two models of uninterruptible power supply units of the Online series - OL5KERTHD and OL6KERTHD.
Models are constructed according to the scheme On-Line with double conversion that provides the effective level of protection of the equipment and does these models by an optimal solution for creation of a system of the guaranteed power supply on industrial enterprises, in telecommunication and server racks, on other objects requiring high reliability and long time of autonomy.
The UPS CyberPower OL5KERTHD, OL6KERTHD models are characterized by the compact size and high density of power. Height of each device only 2U at the power of 5 kVA and 6 kVA, respectively. It is important to note that models at such compactness are already equipped with internal batteries and for ensuring independent operation the user will not need to buy in addition external battery packs. The UPS has electrical power factor equal to unit (kVA = kW) that allows to use a maximum of active power for connection of loading.
For significant increase in battery life of the device support connection to 10 external battery packs, height of each of which is 2U too.
Even at connection of one battery pack we receive totally a system 4U high which on time of autonomy can already compete with devices on li-ion cells and at the same time is considerable win in the price, Antonov Sergey, the development director of the single-phase equipment accents |
Support of hot swap of batteries is implemented, and replacement of batteries is made via a frontal part of the UPS. The UPS front panel is equipped with side latches for simple removal, and captive screws can be weakened manually to open a cover of a battery compartment. Thus, for replacement of the UPS battery it is not necessary to switch off, take out from a rack – replacement is made from a front part without use of any additional tools.
The CyberPower OL5KERTHD and OL6KERTHD UPS models have Technology of alignment of a charge (Battery Equalization Technology) which supports tension of batteries at one level and allows to prolong service life of batteries significantly.
The Technology of fast charging which allows the connected battery modules to return quickly to aggregate capacitance using the built-in charger in each module is implemented.
Devices are equipped with the full-function LCD control panel giving the chance to carry out the UPS setup, and to get acquainted also in real time with key parameters such as loading percent, indicators of network condition, batteries, etc. Krom a LCD panel belongs to the class of the full-color matrixes maintaining color coding. Warnings with color coding provide a clear understanding of a status of the UPS even without detailed studying of indicators – green full-time job, yellow work from batteries, red an overload is highlighted. The automatic turn of the screen for rack-mounting and on a floor is implemented, and for more convenient viewing in a rack configuration the screen can physically bend up to 18 degrees.
Among technical characteristics in addition It should be noted efficiency over 96% in online ESO the mode, high overload capacity (130-150% of loading up to 2 seconds), a broad set of output connectors (2xIEC C19, 4x IEC C13, the terminal strip) and ports (RS232, dry contacts).
In models there is already a preset card of network management of RMCARD205 SNMP for expanded management and remote monitoring which supports all existing protocols and safety certificates. For effective condition monitoring of network and management of the UPS the producer suggests to use the professional software of PowerPanel Business Edition.
The compactness of the device allows to save the area in a server rack, at the same time obviously giving advantage in power. Single electrical power factor, existence of the built-in batteries and a connectivity up to 10 external battery packs, simplification of procedures of service, for example hot swap through a frontal panel, color coding on the display of the screen, and also technology of alignment of a charge do attractive in the technical plan. The standard of the hi-tech device in this class of the equipment is actually created, Victor Tereshchenkov, the lead engineer tells |
We provided a product suitable for high-performance networks, storage systems, switches, the maximum protection of the sensitive, responsible equipment. The innovations provided in the next line of the equipment allow to use more than the power at a smaller density, to effectively use the electric power, makes thrifty use of a resource of batteries, to save on service and every minute to have the complete information about an electric power supply system, Antonov Sergey, the development director of the single-phase equipment comments |
OLS1000EC, OLS2000EC, OLS3000EC, OLS6000EC и OLS10000EC
On March 25, 2019 kompaniyacyberpower provided a series of uninterruptible power supply units of Online SC with topology online in the powers of 1 kVA – 10 kVA. The provided UPSes on price range belong to budget models. For March, 2019 the line includes five UPSes in the Tower body: OLS1000EC, OLS2000EC, OLS3000EC, OLS6000EC and OLS10000EC.
According to the producer, UPSes of double conversion with a signal output in the form of a net sinusoid and will provide effective protection of equipment power supply, crucial, sensitive to quality, zero switching time. The range of use of devices can be rather wide is a server, telecommunication, industrial equipment in the most different industries. UPSes can work with the broad range of input voltage (110-300B for models up to 3 kVA and 110-276B for models of a 6-10kv) without switching to batteries and by that to make thrifty use of their resource. Besides, for increase in service life of joint stock bank in this series the technology of intellectual control of batteries is used.
As noted in CyberPower, younger models differ in compactness. It is possible to connect to OLS1000EC up to four devices, to OLS2000EC to six. In all these modifications output IEC C13 sockets are used, and the adapter for euro the socket is included in the regular package that does the device universal on connection connectors. Models are connected by the power of a 3-10kv via the terminal strip.
The main characteristics of the provided UPS series:
- Topology of double conversion;
- Zero switching time for work from batteries;
- Net sinusoid of voltage output
- Broad range of voltage output;
- Protection against splashes and voltage surges
- Compatibility with generators
- Intellectual battery charging
- Energy-saving technology
- Compact sizes
According to the statement of the producer, devices are simple in installation, do not require special service, have a standard set of the communication ports RS232, USB and the slot for the SNMP card in the senior models. For effective condition monitoring of network and management of the UPS the producer suggests to use the professional software of PowerPanel Business Edition.
According to information for March, 2019, devices are certified and already available to the order.
2018: OL1000ERTX2U, OL1500ERTX2U, OL2000ERTX2U, OL3000ERTX2U и OL10000ERT3UPM
On October 9, 2018 the CyberPower company announced updating online of the UPS of the OL series and emergence in representatives of this series of intellectual functionality.
According to the company, the lineup is provided in powers from 1 to 10 kVA, all a series is represented by five models: OL1000ERTX2U, OL1500ERTX2U, OL2000ERTX2U, OL3000ERTX2U and OL10000ERT3UPM. All models support a connectivity to 10 external batteries that allows to create considerable time of autonomy of operation of the protected equipment.
Representatives of a series can be carried to products in a segment online of the UPS of low power. They will cope powerful voltage surges in network (up to 2400 J) that is crucial when ensuring protection of the responsible equipment against static discharges and voltage surges.
Besides, from a general series online of solutions of this class the OL series is selected with the integrated Intelligent Power Ability system which belongs to significant updating of functionality of devices. The intelligent system is capable to make the analysis of different parameters of the power supply network and recurrence of connection of loading. The saved-up data are analyzed and on the built-in algorithm the optimal operation mode of the UPS is selected - in the absence of loading the source works in the mode of energy saving and does not involve a number of the nodes which are not affecting reliability of a system. Thereby energy consumption of the UPS is reduced, heat release decreases, service life of both a number of elements, and the UPS in general increases. Similarly upside-down - before inclusion of loading, beforehand, the UPS passes into the mode of complete functioning, providing uninterrupted power during the crucial period.
According to representatives of the company, this solution allows to increase efficiency of a system for all life and to reduce ownership cost.
2017: OL6KERT3UPM и OL10KERT3UPM
The CyberPower Systems Ink company announced at the beginning of 2017 expansion of a lineup of the UPS of the Online series. As told CNews in CyberPower, the Online series UPS line with topology of double conversion was replenished with two new three-yunitovymi OL6KERT3UPM models with a power of 6000BA and the 10000 VA OL10KERT3UPM.
In the UPS the high-quality element base and circuit engineering which provide reliability and due level of protection in the field of power supply are used, claim in the company. Zero switching time on batteries and back is characteristic of the Online (OL) series, the signal with a net sine provides a power supply of all crucial power consumers. The GreenPower technology allows to optimize energy costs and to reduce financial expenses of the electric power. UPSes of the Online series are used to protection of the equipment in data processing centers, to protection of network devices, servers and workstations and also industrial equipment.
For January, 2017 in the Online series there are 6 uninterruptible power supply units of different power: OL1000ERTXL2U, OL1500ERTXL2U, OL2000ERTXL2U, OL3000ERTXL2U and also new products of OL6KERT3UPM and OL10KERT3UPM. All UPS models of the Online series are available to acquisition in Russia and the CIS countries.
Among features there are Online series: a signal output in the form of a net sine; technology of Green Power of UPS; topology of double conversion; a form factor for rack-mounting or vertically; protection against electromagnetic, radio-frequency interferences, splashes and shrinkages of tension; connectors of an ultimate load for providing especially important equipment with a power supply at any combination of circumstances; protection of phone/fax/modem/DSL of lines; port of emergency shutdown (EPO); multifunction rotary LCD display; USB and RS 232 ports; expansion of battery life, connection to 10 external battery modules; intellectual control of batteries (SBM); hot swap of batteries; SNMP/HTTP remote network control (option); software of PowerPanel Business Edition.
The topology of double conversion at failures in the electric power, due to additional isolation and other technical solutions, ensures the high level of protection and continuous functioning from the battery with zero actuation time. It stabilizes the output frequency and tension, eliminates line noises which can be caused by industrial conditions or during the work from the generator.
In turn, the net sine at the exit corresponds to a normal signal from network of power supply which ensures continuous optimal functioning of the equipment. CyberPower equipment with a net sinusoid at the exit is developed for electronics in which power supplies with active PFC, and other devices are used.