Elekta Leksell Gamma Knife Icon

Product
Developers: Elekta
Branches: Pharmaceutics, medicine, health care,  Hospitals,  Gospitali

Leksell Gamma Knife Icon is a gamma knife of production of the Swedish company Elekta.

The gamma knife more half a century remains "gold standard" of modern radio surgery: with its help, as a rule, for one session it is possible to cure intra cranial malignant and benign tumors and vascular malformation. And, unlike classical surgery, this type of treatment is nontraumatic, painless and does not require the recovery period.

2018: Leksell Gamma Knife Icon. Description

The Leksell Gamma Knife Icon system allows to lower a dose of radiation of healthy fabrics to a large extent. For December, 2018 the Icon system provides also a number of innovations in a line of the systems of Din knife, such as the integrated visualization, the software for continuous control of delivery of a dose, a possibility of performing treatment without use of invasive methods of fixing, at the same high level of radio surgical accuracy. In view of a tendency to growth of the need for radio surgical treatment, Icon does the Gamma knife system more flexible and simple in use that allows the bigger number of departments to adjust radio surgical treatment of a brain in the conditions of oncological clinics.

Elekta Leksell Gamma Knife Icon (2018)

The system of adaptation in the course of DoseControl treatment

The dose control system in the course of treatment of DoseControl is complex approach to treatment quality control that provides real control of accuracy of leading and delivery of a dose. Integration of radiation control in the course of treatment provides continuous quality control throughout all session of radiation and allows to make clinical decisions in real time.

Tracking of provision in real time

In the Icon Gamma Knife system the identical level of accuracy of leading of a dose is reached at any method of fixing - both when using a frame, and at frameless fixing, with an accuracy of 0.15 mm. If provision of the patient exceeds the limit of available accuracy, a system is blocked, instantly stopping a dose holiday.

Online control of delivery of a dose

The integrated system of stereotaksicheskiya of visualization Cone Beam CT is addition to the radio surgical Icon system. CBCT integrated with the system of positioning of the patient determines stereotaksichesky coordinates in the 3D system, taking into account anatomy of the patient. After comparison of the image Cone Beam CT to earlier received MRT-image, the plan of treatment automatically adapts. Thanks to characteristics of delivery of a dose a system automatically adapts to change of provision of the patient. Dose assessment in the online mode allows to compare distribution of a dose which should be are delivered, in comparison with a dose which was going to be delivered in the course of the treatment session that is carried out directly on the console, and in case of need, the plan can be quickly adapted in the online mode.

High accuracy

All components of the Gamma knife system are integrated into the single system providing the high accuracy of a radio surgical system and extent of preserving of healthy fabrics from influence of radiation. The design with isocentric planning and treatment allows to be convinced that the dose is where it is necessary, and has no impact on other sections of a brain.[1]