Developers: | Dell |
Date of the premiere of the system: | May, 2011 |
Last Release Date: | 2016/10/31 |
Technology: | DWH |
Dell Compellent Storage - the storage system is constructed on architecture which, in addition, provides data movement between storage levels – depending on their real use and requirements to performance. Dell Compellent Storage will virtualize storage infrastructure, opening new levels of efficiency, dynamism and fault tolerance of storage of a corporate class.
Solutions moves ahead the company within the concept of intellectual data management (Intelligent Data Management – IDM).
The IDM strategy of corporation implements according to the company the best ideas in the industry of DWH and meets the growing requirements of modern business. IDM helps the companies of the most different profile and scale of activity to use effectively resources of data centers and also protects from unjustified idle times of systems and provides a rational expense of working time of IT personnel. In general use of strategy of Dell IDM allows corporate customers not only to manage qualitatively data, but also to reduce costs for their storage for 80% – now and in the future.
2016: DWH of the SC series are compatible to solutions for management of data storage
On October 31, 2016 the Dell EMC company announced compatibility of storage systems of the SC series (earlier were issued under the name Compellent) with a solution portfolio for management of data storage, ensuring mobility and data protection.
The Dell EMC company implemented a possibility of use of software and hardware solutions for arrays of storage of the SC series:
Management of storage and mobility of data
- Dell EMC ViPR Suite. This packet consists of ViPR Controller and ViPR Storage Resource Management (SRM), provides the automatic analysis and execution of operations for heterogeneous arrays of storage.
- Dell EMC Intelligent Data Mobility (IDM) technology. The solution provides seamless migration on the new systems.
- Dell EMC PowerPath. The high-performance software management of routes of data transmissions which automates management of routes, their switching at failures and recovery optimizes balancing of loading for ensuring availability and high performance of applications unlike the majority of the multiple path I/O functions (MPIO) implemented at the level of operating systems.
- Dell EMC VPLEX. Provide continuous data availability and their mobility for maintenance of full-time employment of business and critical applications. Provides performance improvement twice, the effective solution All-Flash at cost and a full support of arrays of the SC series.
- Dell EMC CloudArray. The solution for data storage integrated with clouds expands the capacity of the arrays set in DPC of the customer due to use of the cloud capacity, economic on costs.
Data protection
- Dell EMC Data Domain systems. According to IDC, solutions win first place in the market of specialized devices for backup (Purpose Built Backup Appliance), providing the performance measures, best in the class, and efficiency for backup and recovery using deduplication of the data which are stored on SC series arrays.
- Dell EMC Data Protection Suite Avamar for Backup featuring and NetWorker. The solution provides high-performance backup and recovery for SC series arrays, including backup using deduplication on Data Domain, backup on a disk and a tape, long-term preserving in a cloud and also all functions of monitoring of backup, the analysis and preparation of reports.
- Dell EMC RecoverPoint for Virtual Machines. Simple effective solution for operation and disaster recovery of the virtualized applications in the environment of VMware.
Availability
The listed Dell EMC product line for management of storage, protection and mobility of data is available to the systems of the SC series. Support of the solutions ViPR SRM and PowerPath will be implemented at the end of 2016.
2012: Compellent Storage Center based on the SC8000 controller
In June, 2012 the business development manager of DWH of Dell in Russia and the CIS Mihail Vorobyov announced an output corporation on the Russian market of new generation of storage systems of Compellent Storage Center based on the SC8000 controller and upgraded version of 64-bit specialized Storage Center 6.1 OS. He explained that the technological solutions implemented in Compellent Storage Center SC8000 allow corporate clients to reach competitive performance measures in the industry, data storage capacity and also to reduce capital and operating costs of implementation and support of DWH. According to him, the new solution is the next serious step of Dell to implementations of global strategy of creation of the effective, high-performance, scalable intellectual platform of storage of corporate data, including unstructured.
Mr. Vorobyov emphasized that possibilities of architecture of Dell Fluid Data mean the general optimization of network of storage (with intellectual deduplication and compression), the unified management of all infrastructure and also dynamic movement of the stored data in the automatic mode between different levels of infrastructure of storage taking into account the frequency of access to them. All this, according to vendor, allows to guarantee to clients of Dell reliability of storage system at the level of 'five nine', i.e. to provide the 99.999% level of availability.
It selected distinctive feature of new generation of DWH of Dell Compellent which consists in close integration of architecture of storage with the hardware of Dell, including support of Thin Provisioning technology. This technology allows to create volumes of any virtual size, limiting their physical capacity to requirements of the data which are really stored in them. For implementation of Thin Provisioning technology in the Dell Compellent systems software of Dynamic Capacity which, allegedly, completely separates selection of resources of data storage from their use is used. Applying this technology, in most cases, as believe in Dell, clients can save from 40 to 60% of disk space in comparison with a traditional method of reservation of resources of storage.
Mr. Vorobyov noted that SC8000 considerably exceeds the previous generation of controllers on the characteristics. So, this device includes two six-nuclear processors Intel Xeon E5 (2.5 GHz), eight-channel OZU with a frequency of 1333 MHz, six expansion slots PCI-E 3.0 (three — the half size and three — full-size), and existence of technology of air cooling of Dell Fresh Air ensures reliable functioning of DWH in the conditions of the raised temperature condition in DPCs.
The new generation of storage systems of Dell Compellent Storage Center SC8000 supports the Fibre Channel interfaces (with capacity of 8 Gbps), ISCSI (1 Gbps and 10 Gbps), ISCSI/FCoE (10 Gbps) and also the disk storage modules Fibre Channel (FC), SAS and solid-state SSD.
Clients of Dell are given an opportunity of the simplified transition from the used disk arrays of the Series 30 and Series 40 families to SC8000: for this purpose rather current contract on support hardware and the software.
Mr. Vorobyov considers that the output of new generation of storage systems of Compellent Storage Center will strengthen positions of corporation in the Russian market of DWH in which the company, locating two warehouses, became more active in more than 50 cities where support of corporate clients is performed the next working day, and in six cities — within several hours.
Characteristics of Dell Compellent SC8000
Scalability
Each system supports 32 or 128 Gbytes of memory (16 Gbytes or 64 Gbytes on each controller). Each system supports up to 960 disks of SAS in a data storage array. Each body for 3.5-inch disks of SAS contains up to 12 disks of SAS. Each body for 2.5-inch disks of SAS contains up to 24 disks of SAS.
Processor
Two six-nuclear processors (Sandy Bridge) of Intel® 2.5 GHz on each controller
Connection options
- Client ports
- Fibre Channel (4 Gbps, 8 Gbps), iSCSI (1 Gbps, 10 Gbps), FCoE (10 Gbps)
- Support of simultaneous use of several interfaces
Connectivities of the server hardware SAS (3 Gbps and 6 Gbps), Fibre Channel (2, 4, 8 Gbps)
Maximum number of server ports 16 (the Fibre Channel *), 10 (SAS) on each controller — PRIMECHANIYE: it is impossible to connect SATA ports, FC and SATA body to an I/O card of FC8.
- Body of the Fibre Channel and SATA expansion is connected to SC8000 via the expansion card of input-output the Fibre Channel
Storage system
Interfaces of disks Disks of SAS and NL-SAS. Besides, backward compatibility with the existing disks Fibre Channel and SATA Compellent is provided.
In one system it is possible to combine different disks with different transmission rates and rotational speeds
Available disk storage modules:
Solid state drive of SAS (2.5-inch) SAS with a capacity of 200 Gbytes Disk of SAS with a capacity of 400 Gbytes (it will be supported in SC200/SC220 models)
Hard drive Fibre Channel (3.5-inch) 300 Gbyte (15,000 RPM) 450 Gbyte (15,000 RPM) 600 Gbyte (15,000 RPM)
Hard drive of SAS (2.5-inch) 146 Gbyte (15,000 RPM) 300 Gbyte (15,000 RPM) 600 Gbyte 10,000 (RPM) 900 Gbyte 10,000 RPM 1 Tbyte (7200 RPM)
Hard drive of SAS (3.5-inch) 450 Gbyte (15,000 RPM) 600 Gbyte (15,000 RPM) 1 Tbyte (7200 RPM) 2 Tbyte (7200 RPM) 3 Tbyte (7200 RPM)
RAID
- The RAID 0, 5, 6 and 10 DM levels (double mirror) are supported
- In one array of Storage Center any combinations of the RAID levels are possible
- Several RAID levels can be used at one level of a storage system within an array
Body
Controller of a storage system
Height in a rack: 2U Height: 87.3 mm (3.44 inches) Width: 482.4 mm (18.98 inches) with rack fixers 444 mm (17.08 inches) without rack fixers Depth: 755.8 mm (29.75 inches) with a front panel Weight: 19.73 kg (43.5 pounds)
Operating conditions
SC8000 controller
Power supply: two 750 W reserve power capabilities with efficiency of the Platinum level Heat emission: the power source with nominal heat emission of 2891 BTE/h Temperature at operation: from 50 to 95 °F (from 10 to 35 °C) Temperature in an idle mode: from-40 to 149 °F (from-40 to 65 °C) Humidity at operation (without condensation): from 20 to 80% Humidity in the absence of operation (without condensation): from 5 to 95% Input type: NEMA 5-15/CS22.2, n°42
Radiation/security
FCC Class A; EN55022 Class A; EN 61000-3-2/-3-3; CISPR 22 Class A; EN55024/CISPR 24; (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11); EN60950/IEC 60950 Compliant UL Listed (USA), CUL Listed (Canada), TUV Certified (Germany), CE Marking (Europe)